We offer:

  • Storage and process tank with capacities 5m3-120m3 for flammable liquids such as:
    – Tanks for liquid fuels
    – Tanks for fuel additives
    – Tanks for crude oil
    – Tanks for gas
    – Tanks for solvents
    – Other tanks on request
  • Storage and process tank for aggressive and toxic substances such as:
    – Tanks for sulfuric acid
    – Tanks for hydrochloric acid
    – Tanks for sodium methylate
    – Tanks for methanol and ethanol
    – Other tanks on request

Our products

Besides the production of tanks for the petrol market, CGH has many years of experience in manufacturing storage and process-tanks for industrial applications.
We also offer complete installations of sites and tanks according to own or contractor’s documentation.

Crude oil tank

Crude oil tank

Technical specification:

  • Capacity V 100 m3, diameter 2500 mm
  • Double wall, above ground, manufactured in accordance with DIN EN 12285-2
  • Non-pressure tank
  • Working temp. -29 / +50°C
  • External/Internal protection against corrosion
  • Thermal Insulation mineral wool covered with aluminum plate
  • Heating coil

Vertical tank for oil

Vertical tank for oil

Technical specification:

  • Capacity V 80 m3, diameter 2900 mm
  • Single skinned, above ground vertical according to DIN 6618
  • The outside paint is corrosion class C3M
  • Non pressure tank
  • Working temp. -39 / +80°C
  • Isolated, with heating wires

Tank for additives fuel

Tank for additives fuel

Technical specification:

  • Capacity V 50 m3, (3 x 16,88 m3)
  • Diameter = 2500 mm, L = 10800 mm
  • Single skin aboveground tank
  • Manufactured in accordance with EN 12285-2 Class A
  • Material: Stainless steel 304
  • Working temp. -20 / +50°C
  • without painting, passivated steel

Stainless steel tank

Stainless steel tank

Technical specification:

  • Capacity V 30 m3
  • Diameter = 3000 mm, L = 4800 mm
  • Single skin, aboveground, horizontal pressure tank
  • Manufactured in accordance with PED 2014/68/UE and AD2000
  • Material: Stainless steel 304
  • Max. working pressure: 11 Bar

Aboveground double-skinned tank

Aboveground double-skinned tank V 80 m3 according to EN 12285

Technical specification:

  • Storage of diesel for power generator
  • The tank built on a construction to allow movement
  • Equipped with tank loading pump and pump control system
  • Filters, automation, metering

Tanks for polyols and isocyanates

Tanks for polyols and isocyanates

Technical specification:

  • Capacity V 30 m3, diameter 2500 mm
  • Single skin, aboveground vertical tank,
    manufactured in accordance with DIN6618
  • External anticorrosion coating in C3 class, raw surface inside
  • Non-pressure tank
  • Working temp. +5 / +40°C

Aircraft fuel tank

Aircraft fuel tank

Technical specification:

  • Capacity V 10 m3, Diameter 1600 mm
  • Double skin above ground tank produced in accordance with the EN12285 norm
  • Tank designed for aircraft fuel with a water setter and a floating suction arm
  • Stainless steel piping
  • Polyurethane Endopren anti-corrosive coating, internal coating resistant to aircraft fuel
  • Non-pressure tank
  • Working temp. -20 / +40°C

Tank for corrosion inhibitor

Tank for corrosion inhibitor

Technical specification:

  • Capacity V 2,5 m3, diameter 1000 mm
  • Single-wall in the collector, above ground, manufactured in accordance with DIN EN 12285-2
  • Working temp. -29 / +50°C
  • External corrosion protection C3

Water Filter

Water Filter

Technical specification:

  • PED 97/23/EU
  • Working pressure 6 bar
  • Diameter 1600 mm, height of the cylinder 1500 mm
  • Certificate for drinking water PZH
  • Working temp. -29 / +50°C

Sulfuric acid tank

Sulfuric acid tank

Technical specification:

  • Capacity V 10 m3, Diameter 2000 mm
  • Double skin above ground vertical tank produced in accordance with the DIN6618 norm
  • Epoxy-Polyurethane anti-corrosive coating, internal coating resistant to sulfuric acid
  • Non-pressure tank
  • Working temp. -29 / +50°C

Mazout and fuel oil tank

Mazout and fuel oil tank

Technical specification:

  • Capacity V 30 m3, Diameter 2000 mm
  • Double skin above ground tank produced in accordance with EN12285 norm, insulated with heating coil
  • Internal and external anti-corrosion protection
  • Thermal Insulation (mineral wool covered with aluminum plate)
  • Non-pressure tank
  • Working temp. up to +90°C

Hydrofore tank

Hydrofore tank

Technical specification:

  • Capacity V 23 m3, Diameter 1600 mm
  • Single skin above ground tank produced in accordance with the 97/23/EU directive
  • Internal and external anti-corrosion protection
  • Working pressure 10 bars
  • Working temp. +5 to +40°C

Underground pressure tank

Underground pressure tank

Technical specification:

  • Capacity V 10 m3, Diameter 1600 mm
  • Single skin underground tank produced in accordance with EN13445:2002 norm and in accordance with the PED/97/23/EU directive
  • Polyurethane Endopren anti-corrosive coating puncture resistant 10 kV
  • Working pressure 15,6 bars
  • Working temp. -20 / +40°C

Dissolvent tank

Dissolvent tank

Technical specification:

  • Capacity V 30 m3, Diameter 2000 mm
  • Double-mantled above ground tank produced in accordance with the EN12285 norm
  • Epoxy-Polyurethane anti-corrosive coating
  • Non-pressure tank
  • Working temp. -20 / +50°C

Chemical substances tank

Chemical substances tank

Technical specification:

  • Capacity V 80 m3, Diameter 2900 mm
  • Double skin underground tank produced in accordance with the EN12285 norm
  • Polyurethane Endopren anti-corrosive coating puncture resistant 10 kV
  • Non-pressure tank
  • Working temp. -20 / +50°C

The reservoir for the mining industry and the oil and gas transmission

The reservoir for the mining industry and the oil and gas transmission

Technical specification:

  • Standard Capacity from 1 m3 to 100 m3. Smaller or larger volumes on individual request
  • The diameter of a standard 1000 mm, 1250 mm, 1600 mm, 2000 mm, 2500 mm, 2900 mm. Other diameters on individual request.
  • Tanks made of carbon steel as underground or aboveground
  • in accordance with PN – EN, WUDT, DIN, AD2000 and Directive PED/97/23/EU

Aboveground tank for water

Aboveground tank for water

Technical specification:

  • Capacity V 30 m3, diameter 2500 mm
  • Double-skinned, aboveground, manufactured in accordance with EN 12285-2
  • Non-pressure tank
  • Working temp. -29 / +50°C
  • External polyurethane epoxy anti-corrosive protective coating
  • Internal corrosion protection resistant to contaminated ground water